Not sure which protection techniques can be implemented for your electrical equipment intended to be installed and used in the zone system in hazardous areas? Try our FREE Hazcon100 app to learn which protection techniques apply in the zone system and to get a report immediately. Hazcon100 helps users navigate all available protection techniques for zone systems per IEC 60079 series in 10 seconds.

Try the Hazcon 100 app for FREE below:

    Flammable/combustible substance:

    Please see your report below:

    • Flammable Substance: Gas & Vapour (Group II)
    • Classified Area: Zone 0
    • Electrical Protection Methods:
      • Ex ia (Intrinsic Safety)
      • Ex da (Flameproof- Note: this protection only applies to catalytic sensors)
      • Ex ma (Encapsulation)
      • Ex op is (Optical Radiation)
      • Ex op sh (Optical Radiation)

    Please see your report below:

    • Flammable Substance: Gas & Vapour (Group II)
    • Classified Area: Zone 1
    • Electrical Protection Methods:
      • Ex ib (Intrinsic Safety)
      • Ex db (Flameproof)
      • Ex mb (Encapsulation)
      • Ex eb (Increased Safety)
      • Ex pxb (Pressurised)
      • Ex pyb (Pressurised)
      • Ex op pr (Optical Radiation)
      • Ex ob (Oil Immersion)
      • Ex qb (Sand Filled)

    Please see your report below:

    • Flammable Substance: Gas & Vapour (Group II)
    • Classified Area: Zone 2
    • Electrical Protection Methods:
      • Ex ic (Intrinsic Safety)
      • Ex ec (Increased Safety)
      • Ex nA (Non-Sparking)
      • Ex nC (Sealed Devices)
      • Ex nR (Restricted Breathing)
      • Ex dc (Flameproof)
      • Ex mc (Encapsulation)
      • Ex pzc (Pressurised)
      • Ex oc (Oil Immersion)
      • Ex qc (Sand Filled)

    Please see your report below:

    • Flammable Substance: Dusts (Group III)
    • Classified Area: Zone 20
    • Electrical Protection Methods:
      • Ex ta (Protection by Enclosure)
      • Ex ia (Intrinsic Safety)
      • Ex ma (Encapsulation)
      • Ex op is (Optical Radiation)
      • Ex op sh (Optical Radiation)
    Please see your report below:

    • Flammable Substance: Dusts (Group III)
    • Classified Area: Zone 21
    • Electrical Protection Methods:
      • Ex tb (Protection by Enclosure)
      • Ex ib (Intrinsic Safety)
      • Ex mb (Encapsulation)
      • Ex pxb (Pressurised)
      • Ex pyb (Pressurised)
      • Ex op pr (Optical Radiation)

    Please see your report below:

    • Flammable Substance: Dusts (Group III)
    • Classified Area: Zone 22
    • Electrical Protection Methods:
      • Ex tc (Protection by Enclosure)
      • Ex ic (Intrinsic Safety)
      • Ex mc (Encapsulation)
      • Ex pzc (Pressurised)
    Please enter your email address below to receive this report for your record.